Johnson Controls M9106-IGA-2 — Johnson Controls Rotary Air Damper Actuator M9106-IGA-2 [6 Nm · 24VAC/DC · 3-Position Floating]
Rotary Damper & Linear Valve Actuators50/60Hz Global

Johnson Controls M9106-IGA-2

Johnson Controls Rotary Air Damper Actuator M9106-IGA-2 [6 Nm · 24VAC/DC · 3-Position Floating]

Fail-Safe Mode:Non-Spring ReturnControl Signal:3-Position FloatingSupply Voltage:24VAC/DCAuxiliary Switches:0Mechanical Coupling:Screw Terminals (-TP)
Exact OEM Price (EXW)
Factory QuoteVerified RFQ
Verified Supplier: Fourlanos B2B (GR)
Best Verified Replacement
Primary Rating
Lower-rated downgrades blocked
Engineering Verification
✓ 9 Hard Rules Active
View side-by-side spec matrix ↓

Exact OEM Distributor Prices — M9106-IGA-2

EXW · Excl. VAT & Shipping
Fourlanos B2BVerified Supplier
GREXW · Factory Order / Project Quote · Distributor SKU: M9106-IGA-2
Factory QuoteEXW Dispatch
Request Quote →
Johnson Controls Official Catalog
USOfficial OEM Technical Datasheet & Specifications · SKU: M9106-IGA-2
OEM SpecJohnson Controls
Datasheet →
All distributor prices are EXW (Ex Works), excluding local VAT, customs duties, and shipping.Are you an HVAC distributor? List your catalog →

Verified Compatible Replacements (4)

Johnson Controls M9106-IGC-2
Johnson Controls M9106-IGC-2One-Way Spec Upgrade
Johnson Controls Rotary Air Damper Actuator M9106-IGC-2 [6 Nm · 24VAC/DC · 2/3-Position]
✓ Verified Specs: Application Type: Rotary Air Damper Actuator · Fail-Safe: Non-Spring Return · Signal: 2/3-Position ⊇ 3-Position Floating · Supply: 24VAC/DC · Aux Switches: 2 ≥ 0 (Upgrade) · Mechanical Coupling / Variant: Screw Terminals (-TP) · UL / Conduit Standard: 1 · Torque Nm: 6 · Feedback Potentiometer: 0 · Sequence / Stroke Control: 0 · Halogen-Free Cable (LSZH): 0
One-way spec-verified Johnson Rotary Air Damper Actuator upgrade (6 Nm, 2/3-Position, 24VAC/DC, +2 aux switches).
Johnson Controls M9106-AGA-2
Johnson Controls M9106-AGA-2100% Exact Spec Match
Johnson Controls Rotary Air Damper Actuator M9106-AGA-2 [6 Nm · 24VAC/DC · 3-Position Floating]
✓ Verified Specs: Application Type: Rotary Air Damper Actuator · Fail-Safe: Non-Spring Return · Signal: 3-Position Floating · Supply: 24VAC/DC · Aux Switches: 0 · Mechanical Coupling / Variant: Screw Terminals (-TP) · UL / Conduit Standard: 1 · Torque Nm: 6 · Feedback Potentiometer: 0 · Sequence / Stroke Control: 0 · Halogen-Free Cable (LSZH): 0
Strict spec-matched Johnson Rotary Air Damper Actuator (6 Nm, 3-Position Floating, 24VAC/DC, Non-Spring Return).
Johnson Controls M9106-AGA-2N01
Johnson Controls M9106-AGA-2N01One-Way Spec Upgrade
Johnson Controls Rotary Air Damper Actuator M9106-AGA... [6 Nm · 24VAC/DC · 2/3-Position]
✓ Verified Specs: Application Type: Rotary Air Damper Actuator · Fail-Safe: Non-Spring Return · Signal: 2/3-Position ⊇ 3-Position Floating · Supply: 24VAC/DC · Aux Switches: 0 · Mechanical Coupling / Variant: Screw Terminals (-TP) · UL / Conduit Standard: 1 · Torque Nm: 6 · Feedback Potentiometer: 0 · Sequence / Stroke Control: 0 · Halogen-Free Cable (LSZH): 0
One-way spec-verified Johnson Rotary Air Damper Actuator upgrade (6 Nm, 2/3-Position, 24VAC/DC).
Johnson Controls M9106-AGF-2
Johnson Controls M9106-AGF-2One-Way Spec Upgrade
Johnson Controls Rotary Air Damper Actuator M9106-AGF-2 [6 Nm · 24VAC/DC · 3-Position Floating]
✓ Verified Specs: Application Type: Rotary Air Damper Actuator · Fail-Safe: Non-Spring Return · Signal: 3-Position Floating · Supply: 24VAC/DC · Aux Switches: 0 · Mechanical Coupling / Variant: Screw Terminals (-TP) · UL / Conduit Standard: 1 · Torque Nm: 6 · Feedback Potentiometer: 1 ≥ 0 (Upgrade) · Sequence / Stroke Control: 0 · Halogen-Free Cable (LSZH): 0
One-way spec-verified Johnson Rotary Air Damper Actuator upgrade (6 Nm, 3-Position Floating, 24VAC/DC, +feedback potentiometer).

Engineering Spec Comparison Matrix

Deterministic Rule Firewall · Rotary Damper & Linear Valve Actuators
Specification ParameterFirewall Rule
Johnson Controls (Primary)
M9106-IGA-2
Johnson Controls
M9106-IGC-2
Johnson Controls
M9106-AGA-2
Johnson Controls
M9106-AGA-2N01
Johnson Controls
M9106-AGF-2
Application SubtypeExact (=)Rotary Air Damper ActuatorRotary Air Damper Actuator✓ MatchRotary Air Damper Actuator✓ MatchRotary Air Damper Actuator✓ MatchRotary Air Damper Actuator✓ Match
Fail-Safe ModeExact (=)Non-Spring ReturnNon-Spring Return✓ MatchNon-Spring Return✓ MatchNon-Spring Return✓ MatchNon-Spring Return✓ Match
Control SignalSignal ⊇3-Position Floating2/3-Position↑ Upgrade3-Position Floating✓ Match2/3-Position↑ Upgrade3-Position Floating✓ Match
Supply VoltageSuperset24VAC/DC24VAC/DC✓ Match24VAC/DC✓ Match24VAC/DC✓ Match24VAC/DC✓ Match
Auxiliary Switches≥ Min02↑ Upgrade0✓ Match0✓ Match0✓ Match
Mechanical CouplingExact (=)Screw Terminals (-TP)Screw Terminals (-TP)✓ MatchScrew Terminals (-TP)✓ MatchScrew Terminals (-TP)✓ MatchScrew Terminals (-TP)✓ Match
UL / Conduit StandardExact (=)YesYes✓ MatchYes✓ MatchYes✓ MatchYes✓ Match
Rated Torque (Nm)Exact (=)66✓ Match6✓ Match6✓ Match6✓ Match
Feedback Potentiometer≥ MinNoNo✓ MatchNo✓ MatchNo✓ MatchYes↑ Upgrade
Positioning Time (s)Reference60s60s60s60s60s
Grid Frequency (Hz)Reference50/6050/6050/6050/6050/60
Country of OriginReferenceUSUSUSUSUS
Lowest Verified Price (USD)Live Index—————

Frequently Asked Engineering Questions

What is the lowest price for Johnson Controls M9106-IGA-2?

Compare current distributor prices for Johnson Controls M9106-IGA-2 above.

What parts can replace Johnson Controls M9106-IGA-2 (50/60Hz Global)?

Cross-referenced replacement parts matching the 50/60Hz Global electrical specification for M9106-IGA-2 include: Johnson Controls M9106-IGC-2, Johnson Controls M9106-AGA-2, Johnson Controls M9106-AGA-2N01, Johnson Controls M9106-AGF-2. Always verify electrical and mechanical ratings on your equipment nameplate before installation.